topicWorking Inside the Blade Server
S e n d d o c u m e n t c o m m e n t s t o u c s - d o c f e e d b a c k @ c i s c o . c o m
Installing a CPU or Heat Sink
Before installing a new CPU in a server, verify the following:
•
•
•
To install a CPU or heat sink, follow these steps:
Place the CPU on the base with the notches aligned to the pins on the base. See
Step 1
Figure 11
Close the socket latch. See
Step 2
Lock the socket latch into place with the hook. See
Step 3
Attach the thermal pad (also available as a spare A04-BTHP3=) provided with the replacement CPU or
Step 4
server to the bottom of the heat sink, then remove the covering film from the side that will adhere to the
CPU.
Replace the heat sink. See
Step 5
Secure the heat sink to the motherboard by tightening the two captive screws hand tight. See
Step 6
callout 6.
Caution
Make sure that the heat sink fins are aligned to run along the length of the blade server (see
Cisco UCS B440 High Performance Blade Server Installation and Service Note
22
The CPU is supported for that model server.
A BIOS is available that supports the CPU/DIMM and server combination.
The service profile for this server in UCS Manager will recognize and allow the new CPU. This is
especially important if you have been using a single processor and install a second processor.
Inserting the CPU and Replacing the Heat Sink
6
5
3
Figure
Figure
6
2
5
1
11, callout 2.
Figure
11, callout 5.
Figure
4
11, callout 3.
11, callout 1.
Figure
11,
Figure
11).