Epson TM-H6000IIIU Panduan Pengembangan - Halaman 21

Jelajahi secara online atau unduh pdf Panduan Pengembangan untuk Pemindai Epson TM-H6000IIIU. Epson TM-H6000IIIU 32 halaman.
Juga untuk Epson TM-H6000IIIU: Panduan Pengembangan (26 halaman), Panduan Pengembangan (45 halaman)

Epson TM-H6000IIIU Panduan Pengembangan

Section 5. Device Specific Programming

This section describes device specific programming of the MICR devices.

5.1 Obtaining MICR Status in Real Time

It is possible to obtain the MICR's status by using the MICR's DirectIO method or
DirectIOEvent event.
The following is an example program that obtains the MICR status.
Global DIEFlag As Long
Global DIEData As Long
Dim RC As Long
Dim Dummy As Long
Dim Data As String
Dummy = 0
Data = ""
DIEFlag = 0
RC = OposMicr1.DirectIO (MICR_DI_GETSTATUS 'Command number
used
used
If RC = OPOS_SUCCESS Then
'Success
Else
'Error
End If
While( DIEFlag = 0 )
DoEvents
Wend
Status = DIEData
Dummy,
Data)
17
APPLICATION DEVELOPMENT GUIDE
MICR (EPSON TM Series)
Version 3.00 Feb. 2019
'Not
'Not