• Set the jumpers on the control unit to the
appropriate position:
J1 – Determines whether Analogue input AI1
is used as a current or voltage input.
Current
7
AI1
AI2
8
J2 – Determines whether Analogue input AI2
is used as a current or voltage input.
Current
7
AI1
AI2
8
J3 – Drive-to-drive link termination. Set to
ON if the drive is the last unit on the link.
Termination ON
T
Continue with drive start-up according to the
instructions in the ACL30 elevator drive User's
manual (3AXD50000036355 [English]).
Quick installation guide - ACL30-04
Voltage
7
AI1
AI2
8
Voltage
7
AI1
AI2
8
Termination
OFF
T