Whirlpool UXT4236AD Panduan Petunjuk Instalasi - Halaman 8

Jelajahi secara online atau unduh pdf Panduan Petunjuk Instalasi untuk Kap Ventilasi Whirlpool UXT4236AD. Whirlpool UXT4236AD 34 halaman. 30" (76.2 cm) and 36" (91.4 cm) range hood
Juga untuk Whirlpool UXT4236AD: Petunjuk Pemasangan Dan Panduan Penggunaan & Perawatan (28 halaman), Petunjuk Pemasangan Dan Panduan Penggunaan & Perawatan (28 halaman)

Whirlpool UXT4236AD Panduan Petunjuk Instalasi
To wire through top:
1. Mark a line distance "A" from the right of the centerline on the
underside of the cabinet. Mark the point on this line that is
2" (5.1 cm) from back wall. Drill a 1¼" (3.2 cm) diameter hole
through the cabinet at this point.
A. 8³⁄₈" (21.3 cm)
To wire through wall:
1. Mark a line distance "A" from the right of the centerline on the
underside of the wall. Mark the point on this line that is ⁷⁄₈"
(2.2 cm) from the underside of the cabinet. Drill a 1¹⁄₄"
(3.2 cm) diameter hole through the rear wall at this point.
A. 8³⁄₈" (21.3 cm)
Style 1 - Cut Openings for 3¼" x 10" (8.3 cm x 25.4 cm)
Rectangular Vent System
Roof Venting
To make a 4¹⁄₄" x 10½" (10.8 cm x 26.7 cm) rectangular cutout
on the underside of cabinet top and bottom:
1. Mark lines ¹⁄₂" (1.3 cm) and 4³⁄₄" (12.1 cm) from the back wall
on the centerline of the underside of cabinet.
2. Mark lines 5¼" (13.3 cm) to the right and left of the centerline
on the underside of cabinet.
3. Use saber or keyhole saw to cut a rectangular opening for
vent.
4. Repeat steps 1-3 for the underside of the top of the cabinet.
Cabinet cutouts
*From wall, not cabinet frame
8
2" (5.1 cm)
A
from wall,
not cabinet
frame
Centerline
⁷⁄₈" (2.2 cm)
A
Centerline
*¹⁄₂" (1.3 cm)
5¹/₄"
*4³⁄₄"
(13.3 cm)
(12.1 cm)
5¹/₄"
(13.3 cm)
Wall Venting
To make a 3½" x 10½" (8.9 cm x 26.7 cm) rectangle in the
wall:
1. Make 2 lines by measuring ³⁄₈" (0.9 cm) and 3⁷⁄₈" (9.8 cm)
down from underside of cabinet and mark on the centerline
on the back wall.
2. Mark lines 5¼" (13.3 cm) to the right and left of the centerline
on the wall.
3. Use saber or keyhole saw to cut a rectangular opening in the
wall for the vent.
Cabinet
front
³⁄₈"
(1.0 cm)
3⁷⁄₈"
(9.8 cm)
(13.3 cm)
Style 2 - Cut Openings for 3¼" x 10" (8.3 x 25.4 cm)
Rectangular Vent to Round Vent Transition
Roof Venting
To make a 4¹⁄₄" x 10½" (10.8 cm x 26.7 cm) rectangular cutout
on the underside of cabinet bottom:
1. Mark lines ¹⁄₂" (1.3 cm) and 4³⁄₄" (12.1 cm) from the back wall
on the centerline of the underside of cabinet.
2. Mark lines 5¼" (13.3 cm) to the right and left of the centerline
on the underside of cabinet.
3. Use saber or keyhole saw to cut a rectangular opening for
vent.
(12.1 cm)
*From wall, not cabinet frame
To make a circular vent opening on the underside of the
cabinet top:
1. Mark a centerline on the underside of the top of cabinet.
2. Mark a line 5" (12.7 cm) from the back wall on the underside
of the top of cabinet.
3. Use a compass or a circle template to draw a circle with a
diameter that is ¼" (0.64 cm) larger than the vent.
Centerline
¹⁄₄
¹⁄₄
5
"
5
"
(13.3 cm)
*¹⁄₂" (1.3 cm)
5¹/₄"
*4³⁄₄"
(13.3 cm)
5¹/₄"
(13.3 cm)