ABB jokab safety Smile 12SA Tina Manual Petunjuk Asli - Halaman 10

Jelajahi secara online atau unduh pdf Manual Petunjuk Asli untuk Unit Kontrol ABB jokab safety Smile 12SA Tina. ABB jokab safety Smile 12SA Tina 12 halaman. Emergency stop with indication

ABB jokab safety Smile 12SA Tina Manual Petunjuk Asli

7 Technical data

Manufacturer
Address
Power supply
Operating voltage
Total current consumption
Time delay t (in/out)
Voltage supply at normal operation
(protection OK) and 24 VDC supply
voltage
General
Protection class
Ambient temperature
Humidity range
Housing material
Connectors
Size
Weight
Colour
Actuator force (E-stop button)
Actuator travel
Mechanical life
Impact resistance (half sinusoidal)
Vibration resistance (half sinusoidal)
Safety / Harmonized Standards
Approved standards
IEC/EN 61508-1...7
EN 62061
EN ISO 13849-1
EN 954-1
Certificates
10
Smile_Tina_Manual_(English)_v1A
2010-10-19
JOKAB SAFETY AB
Varlabergsvägen 11
S-434 91 Kungsbacka
Sweden
24 VDC +15 %, -25 %
47 mA (57 mA with max information output)
Information output: Max 10 mA
t < 70 µs
Dynamic input: between 9 and 13 volt (RMS)
Dynamic output: between 9 and 13 volt (RMS)
Information output: ~ 23 VDC
IP65
Storage: -30...+70°C
Operation: -10...+55°C
35 to 85 % (with no icing or condensation)
Polyamide PA66, Macromelt, polybutylenterephthalate PBT,
Polypropene PP, UL 94 V0
Smile 10EA Tina: 5-pole cable, 1 m (Smile 10EA Tina)
Smile 11x* Tina: M12 5-pole male
Smile 12x* Tina: M12 5-pole male, M12 5-pole female
* - x can be all models -EA, -EAR, -SA, -SAR
84 x 40 x 52 (L x W x H) – see drawing
~ 65 g
Yellow base, red or black button
22 +/- 4N
~ 4 mm to latch
> 50,000 operations
2
Max. 150 m/s
, pulse width 11 ms, 3-axis
(as per EN IEC 60068-2-27)
2
Max. 50m/s
at 10 Hz, 10 cycles, 3-axis
(as per EN IEC 60068-2-6)
European Machinery Directive 2006/42/EC
EN ISO 12100-1:2003, EN ISO 12100-2:2003,
EN 60204-1:2007, EN 954-1:1996, EN ISO 13849-1:2008,
EN 62061:2005, IEC 60947-5-1:2003 + A1:2009
-9
SIL3, PFHd: 4.66*10
SIL3
Performance level: Pl e, category 4
Category 4
TÜV Nord
www.jokabsafety.com