Important! When installation is complete, make sure that
the seal of each pipe fitting is correct. Use a soapy
solution, not a flame!
The gas supply ramp is on the rear side of the control
panel.
Warning! Before gas connection disconnect the
mains plug from the mains socket or switch off the
fuse in the fuse box. Close the primary valve of the gas
supply.
1
Gas connection point (only one point is applicable
1
for appliance)
Gasket
2
Adjustable connection
3
LPG pipe holder
4
The appliance is set to default gas, to change the
setting choose pipe holder No 4. Always use the
gasket sealing.
Adjustment to different types of gas
Warning! Let only an authorized person do the
adjustment to different types of gas.
This appliance is for operation with natural gas.
With the correct injectors, you can also operate it
with liquid gas.
Warning! Before replacing the injectors, make sure
that the gas knobs are in the off position. Let the
appliance cool off fully. There is a risk of injury.
Injectors replacement
Replace the nozzles when changing the gas type.
1.
Remove the pan supports.
14
2
3
4
2.
Remove the caps and crowns of the burner.
3.
With a socket spanner 7 remove the injectors and re-
place them with the ones which are necessary for the
type of gas you use.
4.
To assemble the parts, do the same steps in reverse.
5.
Replace the rating label (it is near the gas supply
pipe) with the one for the new type of gas supply.
You can find this label in the package supplied with
the appliance.
If the supply gas pressure is changeable or different from
the necessary pressure, you must fit an applicable pres-
sure adjuster on the gas supply pipe.
Adjustment of minimum level
To adjust the minimum level of the burners:
1.
Light the burner.
2.
Turn the knob on the minimum position.
3.
Remove the control knob.
4.
With a thin screwdriver, adjust the by-pass screw
position. If you change from natural gas 20 mbar to
liquid gas, fully tighten the adjustment screw in. If
you change from liquid gas to natural gas 20 mbar,
undo the by-pass screw approximately 1/4 of a turn.
Minimum adjustment screw
1
5.
Make sure the flame does not go out when you
quickly turn the knob from the maximum position to
the minimum position.
Oven injector replacement
1