s
Connections
G
Terminal label
Size 1
Size 2 and 3
G
G
L1
L1
L2
L2
E
L3
N
U / T1
U / T1
G
V / T2
V / T2
L
W / T3
W / T3
I
+
PA
S
H
_
PB
SA
SA
SC
SC
SB
SB
J9+
J9+
J8-
J8-
COM
COM
AIV
AIV
+10
+10
AIC
AIC
+24
+24
FW
FW
RV
RV
The control and reference inputs are electrically isolated from the network.
20
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
U
V
L2
L1
L3
T1
Function
Earth(with heatsink)
Ground
Power
supply
Outputs to motor
Size 1
Size 2 and 3
Option
Braking
braking
resistance
module
connection
connection ATV-16...M2 R ≥ 50Ω / ATV-16...N4 R ≥ 50Ω
N/C contact Safety
relay
common
contacts
N/O contact
d.c.voltage
source input
Common for speed reference 0 V
inputs and control inputs
Voltage speed reference
input
Speed reference input
supply
Current speed reference
input
Control input
supply
Forward control
input
Reverse control
input
COM
AIV
+10
AIC
+24
FW RV
_
+
W
SA SC SB
T2
T3
PA
PB
Characteristics
Usable up to leakage I > 3.7 mA
Depending on size and voltage 2
or 3 mains supply terminals (p3)
230V / 50Hz
230V / 60Hz
See operator guides
VD0C01N906 and VD0C01N907
min : 10mA -
max : inductive load
1.5A -
2.5A -
265 V < U < 370 V
480 V < U < 745 V
0 - 10 V
C
10 V - 10mA max
1 kΩ < R < 10 kΩ
0-20 mA/4-20 mA
C
24 V (from
min : 10mA -
state 1 : U > 11V - I > 6mA
state 0 : U < 5V - I < 2.5mA
Ze = 1.5 kΩ
400V / 50Hz
}
}
M2
N4
460V / 60Hz
C
24V
a
250V
C
30V
Z = 30 kΩ
Ze = 250 Ω
C
C
20V to
30V)
C
24V
Terminal
size
2
mm
10
2.5
2.5
2.5
2.5
2.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5