4 Preparation and Installation instructions
Gas connection
− The gas connection must comply with locally valid standards.
− Make sure that there is no dirt in gas pipes and connections.
− Use gas pipe with the correct dimensions, in order to minimize pressure loss.
− The gas tap must be approved (in the EU this will be the CE mark).
− We advise Pipe work from the meter to the appliance must be of adequate size, with near the
appliance a gas isolator tap that should always be accessible. Place the gas connection in such
a way that this is easily accessible, and that before service, the burner unit can be disconnected
at all times.
Electric connection
− If an adapter is used for the power supply, then a wall socket 230VAC – 50Hz must be mounted
in the close neighborhood of the hearth, as low as possible in the chimney breast.
− In case of a 230[V] electrical connection, provide proper grounding, if applicable.
− If possible, place the receiver after any building work has been completed, if it's not, then protect
the receiver from dust and moisture and possible damage during the building process!
Preparation of the appliance
− Remove the packaging of the appliance. Make sure the gas pipes underneath the appliance are
not damaged.
− Clear a safe space to store the the glass.
− Remove the glass and take the separately wrapped parts out of the appliance.
− Prepare the gas connection to the gas control valve.
Installation of the flue
− Make a hole 3[mm] bigger than the outer flue diameter, either 200[mm] or 150[mm], depending
on the model of the fireplace, for the installation of the wall or roof mounted terminal.
− The horizontal pipes need to rise away from the appliance at the rate of 3 degrees per meter.
− Construct the system starting from the appliance, starting from the fireplace and moving towards
the outside.
− Make sure that you orient and place the pipes correctly: the narrow end pointing towards the
appliance.
− The outside pipe can become very hot, around 150[°C], thus keep at least a 50[mm] distance
from wall surfaces or the ceiling. Make sure to thermally isolate the pipe with thermally resistant
isolation when going through the walls or the roof or next to anything that can be affected by the
emitted heat.
− Thermal expansion can cause, in some occasions, pipes becoming loose, thus in order to
minimize a possibility of such unlikely event taking place, fixate the pipes with a self-tapping
screws at inaccessible places.
− In order to get a pipe of an exact length you can make use of cut down concentric pipe, wall
mounted terminal or roof mounted terminal. To get a smoke sealed connection, the inner pipe
must be at least 20mm longer than the outside pipe.