ASL INTERCOM BS 181 Manuale d'uso - Pagina 5

Sfoglia online o scarica il pdf Manuale d'uso per Alimentazione ASL INTERCOM BS 181. ASL INTERCOM BS 181 8. Single channel power supply
Anche per ASL INTERCOM BS 181: Manuale d'uso (11 pagine), Manuale rapido (4 pagine)

6.0
REAR PANEL CONTROLS & CONNECTORS
3
INTERCOM LINE connectors
These two XLR-3 connectors are for connecting
the user stations, via standard microphone cable.
Pin assignments:
Pin 1: 0 V / ground shield
Pin 2: +30 V power wire
Pin 3: audio wire
4
FUSE holder
A fuse protects the BS 181 against severe internal
damage in case of malfunction in the power

7.0 TECHNICAL SPECIFICATIONS BS 181

Switch Mode Power Supply
mains voltage range: 100 -240 V AC, 50-60 Hz
DC output voltage: +30 V DC (+/-5%)
max. output power: 45 watts
Dimensions & Weight
Width: 176 mm / Height: 42 mm
Depth: 139 mm / Weight: 900 grams
PAGE 5
User Manual BS 181 / May 2013 © ASL Intercom BV
section. Disconnected the power cord before
replacing the fuse. Place the correct fuse in the
holder: T 1250 mA (for all mains voltages 100 –
240V AC)
An extra internal fuse is located on the printed
circuit board. Replace this fuse with a 4A type only.
5
MAINS INLET
IEC Mains connector. For correct wiring and
operation refer to section 4.0.
System Specifications
dynamic range: 80 dB (1 kHz, THD < 1%)
frequency response: 200 Hz – 15 kHz (-3 dB)
call signal (send): 2.8 mA
call signal threshold (receive): +2.4 V DC
operating voltage: 24 - 32 V DC
line impedance: 350 Ω (1kHz), 2.2 kΩ (DC)
audio level: nom. -18 dBu, max. 0 dBu
0 dBu defined as 775 mV into open circuit.
ASL reserves the right to alter specifications
without prior notice