ASL INTERCOM WMC01-B Manuale di installazione - Pagina 6
Sfoglia online o scarica il pdf Manuale di installazione per Controllore ASL INTERCOM WMC01-B. ASL INTERCOM WMC01-B 12. Wall mount controller source select and volume control
8
Installation
1.
Remove the front panel:
a.
Hold the unit upside down.
b.
Undo 4 x M3 screws (if fitted).
c.
Lift the back box.
2.
Make note of the unit's MAC address (A).
The MAC address is used for the configuration of a WMC01 connected via Ethernet.
3.
Set the power supply links as required (B).
4.
Ensure the DIP switches are set as required (C).
C
1 2 3 4
WMC01 – Installation Guide
A
SW 1
SW 2
SW 3
DIP
DOWN
DOWN
DOWN
Switch
up=off
UP
DOWN
DOWN
down=on
DOWN
UP
DOWN
U-0664-0758.docx – Issue: 01 complete, approved
PoE Links
Not fitted
Fitted
SW 4
Configuration
DOWN
Standard settings for operation (default)
•
Configuration: serial or Ethernet
•
Firmware update: via the Ethernet port
DOWN
Bootloader mode: for firmware update via the USB port.
DOWN
Configuration via User Interface: for maintenance only.
Page 6 of 12
RTR Links
Configuration
DC power supply via
Router connections
Fitted
(factory default, as
shown above)
Not fitted
Power over Ethernet
1)
Disconnect power before changing
link settings.
2)
PoE and RTR links must NOT be
fitted simultaneously.
B