AMCI PressPro Genesis Addendum al manuale - Pagina 2
Sfoglia online o scarica il pdf Addendum al manuale per Controllore AMCI PressPro Genesis. AMCI PressPro Genesis 2.
PressPro Genesis Manual Addendum
Solid State Outputs
There are two versions of the PressPro Genesis, one with Mechanical Relay Outputs, the GN3B1-
01A-00, and one with Solid State Relay Outputs, the GN3B1-01B-00. The standard user's
manual covers only the Mechanical Relay output.
The functions of the PressPro Genesis with Solid State relays are the same as those of a unit with
Mechanical relays.
The following diagram shows the location of the inputs and outputs on the GN3B1-01B-00 Solid
State version.
Note: The solid state relays used with the GN3B1-01B-00 are not included with the unit and
must be ordered separately. The two options are KD-6 (DC relays) or KA-3 (AC relays).
Solid State Relay Wiring
+
Each Relay output has two terminals. One is labeled
and the other that shows the Output
+
Number or Function. Connect your power supply to the
terminal and your load to the other
terminal.
+ 1 + 2
Output Number
+
Power
Load
Supply
COM
file: Genesis_press_pro_addendum
date: 1/25/06
20 Gear Drive, Plymouth Industrial Park, Terryville, CT 06786
page: 2
Tel: (860) 585-1254
Fax: (860)584-1973
Web:
www.AMCI.com