AMCOL 6000E Manuale dell'operatore - Pagina 10
Sfoglia online o scarica il pdf Manuale dell'operatore per Controllore AMCOL 6000E. AMCOL 6000E 19. Electronic timing controller for forming and fabricating
Anche per AMCOL 6000E: Manuale dell'operatore (6 pagine)
No or Low Dispersing Air
•
Manifolded dispersing air pressure set too low: adjust.
•
Air hose is kinked or cut: repair or replace.
•
Spray tip is clogged: clean or replace.
•
Spray tip is damaged: replace.
Air in Liquid Line
•
Fluid line is not properly attached to pump: replace hose or fitting.
•
Injector seal is failing: rebuild or replace.
Liquid Drains from Spray Tip
•
Injector check valve is failing: rebuild or replace.
•
Liquid line in single point nozzle assembly is damaged or disconnected: replace
8 T60A Posi-pump Troubleshooting
No Liquid
•
Pump is turned off: turn liquid adjustment screw counterclockwise.
•
Pump is seized: remove, clean, and rebuild.
•
Reservoir is empty: fill.
•
Air pressure is too low: adjust to over 60 PSI.
Bubbles from Injectors
•
Air seals are leaking: replace.
•
Exit fitting is leaking: replace.
Liquid Drains from Injector Outlet
•
Exit fitting is leaking: replace.
•
Evacuation valve is ineffective: clean or replace.
•
Biaxial hose is trimmed incorrectly: be sure hose is cut straight with no burrs or
deformities.
6000E ELECTRONICALLY CONTROLLED PRECISION LUBRICATION SYSTEM
Operator's Manual
P A G E | 9