Sfoglia online o scarica il pdf Manuale di avvio rapido per Sistema interfonico DoorKing 1815-247. DoorKing 1815-247 2. Wiegand keypad / card reader

Wiegand Keypad / Card Reader
These instructions apply to the following DoorKing Products: 1815-247, 1815-248, 1815-249, 1815-250 with circuit
board P/N 1515-009.
When used to control entry through an automated vehicular gate system, the keypad / card reader must be
mounted a minimum of 10-feet away from the gate and gate operator, or mounted in such a way that the
person using the keypad cannot come into contact with the gate or gate operator.
Both the keypad and card reader output their data in a 26-bit wiegand format and must be connected to an access
controller such as the DKS models 1833, 1835, 1837 or 1838. Each device operates independently of each other.
1 Common (Black)
2 Power (Red)
3 Earth Ground
4 Wiegand Common
5 Not Used
6 Data 0 (Green)
7 Data 1 (White)
8 Not Used
1815-864-B-3-16
1 2 3 4 5 6 7 8
Gray
12-24 Volt AC or DC
Orange
12-24 Volt AC or DC
Green
Data 0
White
Data 1
To Access Controller
Black
Common
Red
Power
Keypad OR Card opens door/gate
Connect the keypad terminals to the card reader terminals (Red,
Black, Green, White) and then connect to access controller.
Keypad AND Card opens door/gate
Each device must have separate weigand wire runs to the
controller with each device operating a different controller relay.
Relay contacts are wired in series to device to be controlled.
Suggest setting relay strike times to 5 sec.
Keypad / Card opens different doors/gates
Each device must have separate weigand wire runs to the
controller with each device operating a different controller relay.
Relay contacts are wired to individual devices to be controlled.
White
Green
Red
Black
Gray
Orange
Power for LED Lights