5. Installation tips

The following suggestions should be heeded to prevent potential problems during the life of the product:
do not install the controller in environments with high levels of relative humidity, exposure to direct
pressurised jets of water, high levels of magnetic and/or radio frequency interference.
use cable ends suitable for the corresponding terminals and the cross-section of the wires used; tighten the
cable terminals and slightly tug the cables to check that they are sufficiently tight.
separate as much as possible the probe cables, the keypad cables and sensor cables from the power lines
and cables supplying power to the inductive loads.
protect the controller and the user with suitably rated electrical protection devices, in compliance with the
standards in force of the country of installation.

6. Disposal and cleaning

The controller is made up of metal and plastic parts. These should be disposed of according to the local
legislation in force.
The controller should be only be cleaned on the outside using neutral detergents and/or water.

7. Connection to the power supply

IMPORTANT:
Carefully read this paragraph before connecting the controller! Failure to observe the instructions
contained in this paragraph may cause serious damage to the controller and to the other electrical
devices installed.
The power cable should be connected to the main power supply.
The MICROSPA controller can be connected of power supply:
Single-phase: 230 V, 50/60Hz, 15 A

8. Connecting the 230 VAC loads

The loads operating at mains voltage (230 VAC) must be connected to the controller using the jacks.
Each jack can only accept the type of plug with the contacts set out in a similar manner. For this reason, before
making the connection, check that the jack corresponds to the plug.
For good mechanical tightness and protection against water penetration, insert the plug fully into the jack.
WARNING
The jacks on the controller that are not used are still connected to mains voltage.
To prevent personal injury or material damage and maintain conformity to safety standards, these must
be covered on the outside so that internal contacts cannot be reached by sprays of water and are not
accessible.

9. Connecting the light

The controller is fitted with a cable for connecting the spa lighting. This cable is located on the right side of the
controller, and supplies 12 Vac, 2 A.
For the connection of the halogen lamp simply fit the light bulb into the bayonet at the end of the cable.
D:\LAVORO\CONTROLLI SPAS\MANUALI INSTALLAZIONE\MICROSPA\Instruction Microspa.doc
Astrel S.p.A.
Via Isonzo, 21/E – 34070 Mossa (GO) Italy
Tel. (+39) 0481 637301 r.a.-Fax (+39) 0481 637362
e-mail: [email protected] – www.astrel.it
Cap. Soc. € 619200. i.v.
Tribunale di Gorizia n. 3505
R.E.A. n. 049936 – M/351122
Part. IVA e Cod. Fisc. 00187070313
Sheet 3/7