Sfoglia online o scarica il pdf Manuale per Adattatore Astro Pneumatic ADG100. Astro Pneumatic ADG100 7. Grease gun drill adapter
MODEL:
BULK LOADING
FILL WITH SCOOP OR WOODEN TOOL
1. Remove the gun head from the container tube.
2. Draw back the plunger handle entirely. Fill loose grease into empty container tube.
3. Reassemble the gun head onto the container tube. Release the plunger rod.
Push down the plunger handle.
IMPORTANT
• If gun loses its prime, it is due to air pockets in the lubricant.
TO REPRIME:
• Unscrew container tube 1-2 turns. Withdraw rod, push rod into container tube to expel the air pockets.
• Draw back plunger rod fully and release quickly. Repeat several times. This will help exert force to move the
rubber plunger to enter the cartridge and expel the air pockets which is essential for a grease gun to work.
• Push plunger rod all the way in, tighten the head to the container tube.
• Now your grease gun is ready to use.
IX. TROUBLE SHOOTING
Problem
Tool runs normal but
does not output grease
Plunger does not enter
the grease cartridge
Leakage from
outlet of gun head
ADG100
Problem Cause
Air pocket inside
container tube
Size of cartridge
not standard
The end edge of
cartridge is rough
or irregular
Hose is not
tightened securely
PRODUCT TYPE:
GREASE GUN DRILL ADAPTER
Recommendation
• Take off hose from Gun Head.
• Unscrew container tube 1-2 turns from Gun Head.
• Withdraw plunger rod, push plunger rod into
container tube to help expel the air pockets.
• Draw back plunger rod fully and release quickly.
• Operate power tool to check flow of grease.
• Repeat above steps if necessary.
• Re-tighten container tube to gun head firmly.
• Re-screw hose securely.
• Grease gun is ready for use.
• Check the size of cartridge corresponds
to specifications.
• Grease the plunger or cartridge end to help
it enter cartridge.
• Always use standard size of cartridge.
• Check that the end edge of cartridge should not
be damaged or folded and remains in exact
round shape. Otherwise the plunger rubber will
be prevented from entering the grease cartirdge.
If this case happened, correct above errors.
• Do not re-use the empty grease cartridge.
• Remove used cartridge from container tube
when bulk loading.
• The thread size is tapered, this means if the
hose is not tightened enough it will not seal.
Tighten with wrench.
Page 6