Baumer HMG 10-SSI Manuale di installazione e istruzioni per l'uso - Pagina 19
Sfoglia online o scarica il pdf Manuale di installazione e istruzioni per l'uso per Convertitore multimediale Baumer HMG 10-SSI. Baumer HMG 10-SSI 36. Absolute encoder with magnetic sensing
5.4
LED function displays
LED
INC1
(additional output
incremental 1)
INC2
(additional output
incremental 2)
Status
Speed
5.5
Speed switch - Switching characteristics
Event
During initialisation
After initialisation and
speed ≤ -ns (off)
-ns (off) < speed ≤ -ns (on)
-ns (on) < speed < +ns (on)
+ns (on) ≤ speed < +ns (off)
+ns (off) ≤ speed
High resistance
Resistance between
SP+ and SP-
Low resistance
n
= Speed
+ns (on) = Activation speed at shaft rotation in positive rotating direction*
+ns (off) = Deactivation speed at shaft rotation in positive rotating direction*
-ns (on) = Activation speed at shaft rotation in negative rotating direction*
-ns (off) = Deactivation at shaft rotation in negative rotating direction*
* See
section 6, page
MB244EN - 11171691, 16A3, Baumer_HMG10-SSI_II_EN
Red
Undervoltage
Overload
Over-temperature
Undervoltage
Overload
Over-temperature
Internal error
Speed higher switching speed
(overspeed)
-n
-ns (off)
22�
ELECTRICAL CONNECTION / LED FUNCTION DISPLAyS
State of the speed switch output
High resistance (overspeed)
High resistance (overspeed)
State unchanged
Low resistance (no overspeed) after initialisation if
the encoder is rotating between the switching range
during initialisation�
Low resistance (no overspeed)
State unchanged
Low resistance (no overspeed) after initialisation if
the encoder is rotating between the switching range
during initialisation�
High resistance (overspeed)
-ns (on)
0
Green
OK
OK
OK
Speed lower switching speed
+ns (on)
+ns (off)
+n
15/32