7
|
Disassembly
Ill. 18: Uninstall encoder, mounting device and coupling
1
Coupling
3
Attachment device, customized
Tools
2.5 mm
n
n
Instruction:
a) Disconnect all electrical connections.
b) Loosen the the coupling on the drive shaft.
Observe the notes in the data sheet and the coupling assembly instructions.
c) Loosen the encoder from the drive's attachment device.
d) Remove the encoder drive's attachment device.
e) Uninstall the attachment device.
f) Remove the coupling from the encoder.
34
1
10 mm
Operating Manual
2
3
2
Mounting screw M6x16 mm for attach-
ment device (ISO 4017)
Baumer Hübner
PMG10 & PMG10P DeviceNet | V1