7.1.3
Detaching the encoder from blind hollow shafts
1
Cheese head screw M8x45 mm (ISO
4762)
Werkzeug
6 mm
n
n
Instruction:
w Slide encoder off the shaft by loosening the cheese-head screw and support the shaft using
a wrench.
Result:
ü
The encoder comes off.
V1, T1 | HMG10 & HMG10P EtherNet/IP
17 mm
1
Operating Manual
Disassembly
|
7
37