Power Supply Information
Input Voltage
Range
Min (V)
Range 1
90
Range 2
180
Output Current Capacity
Output
Nom Out (Vdc)
1
3.3V
2
5.0V
3
12.0V
4
-5.0V
5
-12.0V
* Total output power for 3.3V and 5V combined shall be 210W
Output Voltage Regulation, Ripple, and Noise
Output Voltage Limits (Vdc)
Output
Min
1
3.17V
2
4.80V
3
11.40V
4
-4.50V
5
-10.92V
6
4.75V
Regulatory Information
Safety
The power system meets all applicable clauses for UL 1950 2nd edition
without D3 deviations. The power system passes all tests for CUL and TUV
safety.
EMI
The power system, operating with resistive load, meets FCC class B and
CISPR 22 class B conducted limits.
AP2500 Hardware Reference Guide
III. Appendix
Nom (V) Max (V)
120
132
230
265
Min (A)
1.4
2.4
0.5
0
0
Nom
Max
3.30V
3.46V
5.00V
5.25V
12.00V
12.60V
-5.00V
-5.50V
-12.00V
-13.20V
5.00Vsb
5.25V
Max (A)
30*
43*
12
0.5
0.5
Ripple/Noise
Maximum
50mVp-p
50mVp-p
120mVp-p
120mVp-p
120mVp-p
120mVp-p