Code settings
0 * Code not active
Max. 9999
Function of Batch counter
0 * As total sum counter (counting parallel to main counter)
1
As batch counter (counting automatically when P2 is reached)
Multiplication of secondary counter (only if line 41 = 1)
1 * Default
Max. 999
Actual value correction (only if line 31 = 4)
0 * No correction value
Max. 999999
Display following a power failure
0 * no power failure display
1
Power failure display, display flashes (cancel with
Baud rate
0 * 4800 Baud
1
2400 Baud
2
1200 Baud
3
600 Baud
Parity
0 * Even parity
1
Odd parity
2
no parity
Stop bits
0 * 1 Stop bit
1
2 Stop bits
Address
0 * from
99
to
Assignment of output values via interface (line 31 = 5)
0 * Display value
1
XP
2
P1
3
P2
4
SC
5
∑
6
7
SF
RS422: Control of connections TxD+ or TxD
0 * Switched in transmission direction during transmission, in
reception direction during reception
1
Always in transmission direction
The dash line indicates the end of the third programming field.
As soon as
is pushed again, the instrument will automatically
return to the operator level. Programming can, however, be shut
down on any line by simultaneously pushing
the keys depressed for ca. 2 seconds).
www.baumer.com
(7 data bits)
(7 data bits)
(8 data bits)
NE230
key)
and
(keeping
39