Amprobe VPC-10 Manuale d'uso - Pagina 11

Sfoglia online o scarica il pdf Manuale d'uso per Strumenti di misura Amprobe VPC-10. Amprobe VPC-10 16. Voltage & continuity tester
Anche per Amprobe VPC-10: Manuale di istruzioni (2 pagine)

OPERATION

Note: All function operations described hereafter are via
the stationary "Yellow" probe for positive (+) polarity
and the attached "Black" probe for Ground reference (-),
or otherwise specified.

Automatic Operation

The tester automatically turns on when you place the
probes across a complete circuit. The tester selects
continuity or DC or AC voltage mode based on the
resistance or voltage between the probes. The tester
automatically turns off when you remove the probes
from the complete circuit.

Voltage Measurement

Connect test leads across the source or load under
measurement, the LED turned on at between 70% and
100% of their rated voltages.
DC Voltage: 600V maximum
AC Voltage: 600V rms maximum, 45 to 66Hz

Continuity Testing

Turn off circuit power before testing. Beeper indicates
shorts lasting 1ms or longer. Short circuit=0-85KW

SPECIFICATION

Function
AC voltage (V) 24,120,208,240, 277,
DC voltage (V) 6,12,24,36,48, 110,220
Continuity Test: Audible threshold 0-85kW, Continuity
beeper 2KHz
Maximum Voltage Between any Terminal and Earth
Ground: 600V DC; 600V AC rms, Overvoltage Category III
(Refer to Figs 1, 2 and 4)
(Refer to Figs 3)
Range
480,600
5
Accuracy
-30% to 0% of
reading
-30% to 0% of
reading