Trouble Shooting
Problem
Possible Causes
1. Grease missing around the suction filter.
The pump continues
2. There is a grease leak at some point
to operate after the
gun trigger has been
of the circuit.
3. Valve (part No. 47) closes incorrectly due
released.
to dirt or wearing.
1. Air bags in the grease drum.
Reduction of the
2. Silencer (23) dirtied.
grease delivery.
3. Blocked at some point of the grease circuit.
Or reduced pressure
4. Ball valve (37) closes incorrectly due to dirt
in the grease
delivery.
or wearing.
5. Damaged O-Ring (43).
Grease leaks through
Seal set (28) damaged.
the air exhaust.
If the pump has anything wrong, please contact Alemlube.
We do not recommend customers repairing the pump themselves.
Storage and Maintenance
Pumps are delivered in appropriate cardboard boxes. Packaging material should be properly disposed of.
Handling and storage of the pump do not require any special procedures. Dust in the compressed air can slow down
or even block the motor cylinder. The following steps may prevent this from happening:
1. Introduce 50 grams of Vaseline oil or other lubricator into the air inlet hole.
2. Turn on the pump for several minutes until the moving parts are fully lubricated.
3. Repeat the above operation if necessary.
4. The above steps should be carried out on a weekly base.
For the pumps that are attached with compressed air treated equipment please empty the water retained
in the reservoir of the filter-purger frequently.
For the pumps that are attached with a lubricator, please pay close attention to the lubricator's grease level
and refill with NLGL-2 when necessary.
Note:
The user should perform only routine maintenance operations (such as filters, silencers, cleaning...) in order
not to damage or compromise its safety. Contact Alemlube when the pump needs further maintenance.
NSW/ACT
QLD/PNG
TEL: (02) 9939 0711
TEL: (07) 3889 8480
FAX: (02) 9939 0411
FAX: (07) 3889 8490
OWNER'S TECHNICAL MANUAL
20KG Grease Kit
VIC/TAS
TEL: (03) 8787 8288
FAX: (03) 8787 8266
Visit our website at
www.alemlube.com.au
Solutions
1. Remove cover and take out pump and follower plate.
Compact grease and fill the drum or replace it for a full one.
2. Check and tighten unions. Repair the leak.
3. Disassemble and clean valves. Replace them if damaged.
1. Remove the cover and take out the pump and the follower
plate. Compact the grease and fill the drum.
2. Clean or recharge silencer.
3. Use clean grease.
4. Replace damaged elements.
Replace damaged elements.