General Description

A complete 3M Portable Compressed Air Filter and Regulator Panel with CO Filtration and
Monitor will operate as follows. (Fig. 1)
1. Air entering the four-stage filtration system at the inlet (A) is usually contaminated with oil,
water, dirt, rust, scale and vaporous hydrocarbons.
2. As the air passes through the first stage of the prefilter (B), particulate matter 3.0 microns and
larger are trapped and retained.
3. The air then enters the second stage of the prefilter (C) which traps particulate matter larger
than 0.3 microns and coalesces liquid aerosols with an efficiency rating of 99.97%. The liquid
contaminates are trapped in the lower chamber of the prefilter and expelled through the
automatic float drain (D).
4. The third stage (E) contains a bed of odor absorbing activated charcoal.
5. The fourth stage (F) contains a low temperature catalyst which converts approximately 60% of
any carbon monoxide to carbon dioxide.
6. The air is then passed through the air pressure regulator (G), which is used to adjust the air
pressure going to the respirators.
7. A sample of the filtered air is taken at (H) and passed through the carbon monoxide monitor (I).
8. The carbon monoxide monitor continuously checks the carbon monoxide concentration and
digitally displays the amount present in ppm (parts per million). An audio and visual alarm will
alert operators if carbon monoxide concentrations exceed a preset level (10 ppm USA;
5 ppm Canada).
W WARNING
The 3M™ Portable Compressed Air Filter and Regulator Panel 256-02-00, with CO Filtration
and Monitor should not be used when the air entering the filtering system is oxygen deficient.
These units will not increase the oxygen content of oxygen deficient air. Use with oxygen
deficient air may result in sickness or death.
Fig. 1
4

SPECIFICATIONS

Inlet pressure (max.)
125 psig static (8.6 bar)
Rated air flow (max.)
50 scfm (1416 L/min)
Inlet pressure (recommended)
90-120 psig (6.2-8.3 bar)
Outlet pressure range
0-125 psig (0-8.6 bar)
Operating temperature range
68-150°F (20-65°C) (compressed air temperature
at inlet of panel)
0-110°F (¯17-43°C) (ambient air temperature)
Dimensions
23.25"L x 20.75"W x 9"D
(590mm x 5276mm x 229mm)
Weight (includes monitor)
31 lbs. (14.1kg.)

3M Respirator Capacity

The 3M filter and regulator panel with CO filtration is supplied with quick-disconnects at the
outlet for connection of up to four (4) supplied air respirators. The actual number of respirators
that may be connected to the filter and regulator panel is dependent on the inlet pressure to the
panel and the airflow and pressure requirements of the respiratory protection. (Fig. 2) As the air
passes through the panel there is resistance to flow called pressure drop. The more airflow
through the filter and regulator panel, the greater the pressure drop. The air control devices
approved for use with the 3M respirators must be operated within the supply pressure ranges and
hose lengths stated in their User Instructions. Use Figure 2 along with information on the
maximum airflow consumption, supply pressure ranges, and approved hose lengths as stated in the
User Instructions for the 3M air control device to determine the number of respirators of a specific
type that may be connected to the panel.
Fig. 2
5