10 A. Metal Blades and Safety Cages: If your
fan is one with metal blades and safety
cages, remove protective plastic sleeve from
the motor shafts, then and attach the back
side of the safety cage. Next, attach the
blade. Handle your blades carefully
otherwise you will bend the blade irons and
cause your fan to vibrate when in use.
Finally attach the front side of the cage with
Atlas medallion oriented correctly. Caution:
The set screw in the blade hub must be
counter-sunk into the bore-hole on the
flattened side of the motor shaft - or else the
blades may disengage from the motor shaft
during operation.
10 B. Wooden Blades: If your fan is one with
wooden blades, attach your blades as the
last step in the assembly process. Do not
attach them now. Attach them in step No.:
13. Handle your blades carefully otherwise
you will bend the blade irons and cause your
fan to vibrate when in use.
11. Now lift the motor assembly into position
and place the hanger ball into the hanger
bracket. Rotate down rod until the "Check
Tab" has dropped into the "Registration Slot"
and the down rod and ball assembly seat
firmly. The down rod and ball assembly
should not rotate if this is done correctly.
12. An additional safety support is provided to
prevent the fan from falling. Secure the
safety cable to the ceiling joist with screw
and washer. (Fig. 5)
13. Remove protective plastic sleeve from the
motor shaft and attach your wooden blades.
Ignore this step if you have metal blades, as
they should already have been installed.
Make sure that the set screw in the blade
hub is counter-sunk into the bore-hole in the
motor shaft - or else the blades may
disengage from the motor shaft during
operation.
Screw
Safety cable
Registration
slot
5
Figure 5