Atlas fan company Acqua Manuale di istruzioni - Pagina 8

Sfoglia online o scarica il pdf Manuale di istruzioni per Ventilatore Atlas fan company Acqua. Atlas fan company Acqua 18. Ceiling mounted rotational fan ac 220-240v~, 50/60hz
Anche per Atlas fan company Acqua: Manuale di istruzioni (10 pagine)

Atlas fan company Acqua Manuale di istruzioni
5. Connect the white, neutral receiver neutral
wire to the terminal block "N" hole. Connect
the blue,
receiver
Live/hot
terminal block "LI" hole. Connect the black,
receiver
Live/hot
Live/hot
block "L" hole. (Fig. 10 &11)
6. Be sure to snap together the male and
female plugs. (Fig. 10 &11)
wire to the
Live/hot
wire to the terminal
Blue (LI)
Receiver
Black (L)
White (N)
Live/Hot
(household)
Neutral
(household)
Black
(receiver)
White (N)
Blue (LI)
Black (L)
Terminal
block
Female plug
Male plug
(from fan)
7
Black
("LI" to fan)
Brown
("L" to fan)
Blue
("N" to fan)
Female plug
Green/
Ground
Male plug
(from fan)
Figure 10
Green/
Ground
(household)
Green/Ground
Green/Ground
(Hanger bracket)
White
(receiver)
RECEIVER
Green/Ground
(fan)
Black (LI)
Brown (L)
Blue (N)
Green/Ground
(downrod)
Figure 11