[*] [*] [*] [*], the buzzer will beep three times and zone 2 light will go out to show that the code has been
removed.
5. Follow the instructions in 3 or 4 for programming or removing any of the other additional codes.
6. To program access codes 9 to 16, press 9 to toggle into the upper code region. Zone lights 1 to 8 now rep-
resent access codes 9 to 16 (light 1 is code 9.... light 8 is code 16). The "Ready" and "Armed" LEDs will flash to
indicate that the user is in the upper programming region. Program or remove access codes 9 to 16 as stated
in 3 and 4 above. Press 9 again to toggle back down to the lower region (access codes 1 to 8).
7. Do not try to remove the Master Code (1st code). The Master Code may be changed but it must not be
removed. When changing the Master Code be sure to enter a valid 4 digit number (use only number keys 0
to 9). Do not enter [#] or [*] as one of the digits. If the Master Code is forgotten and the panel is left disarmed,
program a new Master Code using the [*][8][Installer's Code][25] command. If the Master Code is forgotten
and the panel is left armed, use the 2nd Master Code to disarm the system. If the 2nd Master Code is not
programmed then the entire programming can be reset to factory default by using the "Hardware Reset"
method described on page 24.
8. To successfully program or remove additional codes, the panel must be put into the code program mode
by following step 1 followed by steps 3 or 4. Note that if no key entry is made for 2 minutes the panel will go
back to the normal arm/disarm mode, after which step 1 must be repeated to get back into the code pro-
gram mode.
9. To exit the code program mode press [#].
To review:
programming a new code;
enter [*] [5] [Master Code] [1 to 8] [4 digit code], or
[*] [5] [Master Code] [9] [1 to 8] [4 digit code]
eliminating an existing code;
enter [*] [5] [Master Code] [2 to 8] [* * * *], or
[*] [5] [Master Code] [9] [1 to 8] [* * * *].
Note: The access code numbers must be entered as
one digit. E.g. 2, 3,......, 7, 8.