DSC PowerSeries PC1616 Manuale di installazione
Sfoglia online o scarica il pdf Manuale di installazione per Sistema di sicurezza DSC PowerSeries PC1616. DSC PowerSeries PC1616 13. System
enhancement
module
Anche per DSC PowerSeries PC1616: Manuale di installazione (17 pagine), Manuale rapido (4 pagine), Manuale di installazione (20 pagine), Manuale (18 pagine)
To download the full installation and user manuals and register your product, please visit:
dsc.com/m/29008247 or scan the QR code to the right.
PC1864/PC1832/PC1616 Alarm Controller v4.X Installation Guide
This document provides information to meet UL Listing requirements for the PowerSeries PC1616, PC1832 and PC1864 alarm controllers. Use this document in
conjunction with the PowerSeries PC1864/PC1832/PC1864 Installation Manual.
Technical Summary
OUT Of THE BOX
Qty
1
q
Cabinet
q
Qty
1
PC Module
q
Qty
1
Installation Guide
Qty
1
q
User Manual
Qty
2
q
Cabinet Label
Qty
1
q
Cabinet Door Plug
Qty
5
q
Standoffs
q
Qty
16
5.6KΩ Resistors
q
Qty
1
2.2KΩ Resistor
Qty
1
q
1.0KΩ Resistor
Qty
1
q
Grounding Kit
SPECIFICATIONS
Temp Range:
0°C-49°C (32°F-120°F)
Humidity (max):
93%R.H.
Power Supply:
16.5VAC/40VA @60Hz
Current Draw: (Panel)
110mA (nom.)
Aux+ Output:
11.1-12.6VDC/700mA
Bell Output:
11.1-12.6VDC/700mA
Compatible Devices
Keypads
(Backward compatible with all PowerSeries keypads)
PK55XX Keypad . . . 125mA (max.)
RFK55XX Keypad . . . 135mA (max.)
LCD5511 Fixed Message LCD Keypad . . . 85mA (max.)
LED5511Z 8-zone LED Keypad . . . 100mA (max.)
PC5003C . . . 222x298x78mm (11.3x11.7x3.0in)
PC500C (residential burg only) 213x235x78mm (8.4x9.25x3.0in)
PC4050CAR (UL commercial burg) 305x 376x124mm (12.0x14.8x4.9in)
CMC-1 (UL commercial burg) 287x297x76mm (11.3x11.7x3.0in)
Suttle, SAE 14 . . . 355.6 x 362x 95mm (14x14.25x 3.75in)
Suttle, SAE 21 . . . 533.4 x 362x 95mm (21x14.25x 3.75in)
Suttle, SAE 28 . . . 711.2 x 362x 95mm (28x14.25x 3.75in)
Suttle, SAE 42 . . . 1066.8 x 362x 95mm (42x14.25x 3.75in)
Installation
Mount additional modules in cabinet using stand-offs provided, then mount cabinet in a dry, protected area with access to unswitched AC power. Install hardware
in the sequence indicated. Do NOT apply power until installation is complete.
NOTE: All wiring entry points are designated by arrows. All circuits are classified UL power limited except the battery leads. Minimum 1/4" (6.4mm) separation
must be maintained at all points between power limited and non-power limited wiring and connections.
WARNING: This manual contains information on limitations regarding product use and function and information on the limitations as to
liability of the manufacturer. The entire manual should be carefully read.
Features
On-board Zones
Hardwired Zones
Wireless Zones
Keypad Zone Support
On-board PGM Outputs
PGM Expansion
Keypads
Partitions
User Codes
Event Buffer
Transformer Required
Battery Required
Bell Output
Cabinets
PC1616
6
16 (1xPC5108)
32 (3xPC5108)
32
ü
PGM 1 - 50mA
PGM 1 - 50mA
PGM 2 - 300mA
PGM 2 - 300mA
8x50mA (PC5208)
8x50mA (PC5208)
4x500mA (PC5204)
4x500 mA (PC5204)
8
2
47 + Master Code
71 + Master Code
500 Events
500 Events
16.5VAC/40VA
16.5VAC/40VA
4Ah / 7Ah/14AHr
4Ah / 7Ah/14AHr
12V/700mA (cont)
12V/700mA (cont)
TL-250/TL300 Communicator . . . 275/350mA
GS2060/GS2065 (GPRS/GSM only) . . . 65mA
GS2060-SM (GPRS only) . . . 90mA
TL260GS/TL265GS (Ethernet/GPRS) . . . 100mA
TL260-SM (Ethernet only) . . . 100mA
TL260GS-SM (Ethernet/GPRS only). . . 120mA
PC5100 2-wire Interface 40mA plus devices to 170mA max.
RF5132-433 Wireless Receiver . . . 125mA
RF5108-433 Wireless Receiver . . . 125mA
PC5108 Zone Expander . . . 30mA
PC5200 Power Supply . . . 20mA
PC5204 Power Supply with 4 Programmable Outputs. 30mA
PC5208 Low Current Programmable Output Module . 50mA
Escort5580 Telephone Interface Module . . . 130m
*The T-Link TL-150 is not UL/ULC listed
PC1832
PC1864
8
8
64 (7xPC5108)
32
64
ü
ü
PGM 1/3/4-50mA
PGM 2-300mA
8x50mA (PC5208)
4x500mA (PC5204)
8
8
4
8
94 + Master Code
500 Events
16.5VAC/40VA
4Ah / 7Ah/14AHr
12V/700mA (cont)
Modules