Danish Interpretation Systems
Speaking too fast)
When pushing this button the LED in the Speaking
too fast button lights in 10 sek. in all IS 6132 units.
And at the same time the Speaking too fast
indication will be indicated in units supporting this
function (as some CM6xxx units or PC with SW
6000 software)
Call
Not implemented.
A-Engaged
The yellow LED is lit if the channel is occupied
either by another interpreter or the interpreters set
itself occupies the channel.
B-Engaged
The yellow LED is lit if the channel is occupied
either by another interpreter or the interpreters set
itself occupies the channel.
Manual 01 18 04445, Printed in Denmark, 02/2003 CHN
Error indication
If errors occur in the communication with the CU it
will be indicated by the interpreters set. The set has
two error thresholds. The first threshold is reached
when audio-data from the CU contains too many
errors for the sound to be reproduced correctly. This
is indicated by a black matrix in the normal
operation display and by the communication display
when the set is un-initialised. The second threshold
is reached when the frame error rate reaches a
higher predefined value. When this happens the set
will enter the communication status display
regardless of the state the set was in before errors
occurred.
The error status is checked every 5 seconds and
when no errors has occurred since the last check the
set enters the operation mode it was in before errors
was detected.
User Manual