Abus WIRELESS ALARM SYSTEM Manuale d'uso - Pagina 11
Sfoglia online o scarica il pdf Manuale d'uso per Sistema di sicurezza Abus WIRELESS ALARM SYSTEM. Abus WIRELESS ALARM SYSTEM 14.
Follow Me
7.6
Under Follow Me, you make the settings for the events that cause an alarm to be transmitted by telephone. You also define the
remote access phone code that has to be entered if you want to access the system from outside by telephone. Select Installer ->
Follow me.
After making your settings, confirm the dialog with OK. You can now make the same settings for resetting events, i.e., if the event is
reset. Another dialog box opens, but not all event resets are available.
After making all settings, send the data to the client. Click
The data is transferred to the client and the Application succeed dialog box opens. The client emits a brief signal tone.
Confirm the dialog with OK.
Enter the remote access phone
code via the keyboard. This code
has to be entered by telephone to
dial into the system.
For every phone number, double-
click Event. A new menu opens.
Select the events for which you
want to be called by phone.
Intruder alarm – The call starts when an intruder alarm is triggered.
Fire alarm – The call starts when a fire alarm is triggered.
Emergency.Alarm – The call starts when an emergency alarm is triggered.
Panic alarm – The call starts when a panic alarm is triggered.
General tamper – The call starts when a tamper alarm is triggered.
Remote programming – The call starts if someone attempts to program the alarm system
from outside.
AC off – The call starts if a power failure is registered.
Duress – The call starts if the system is deactivated by a duress code.
Arm (by partition) – The call starts if the system or a partition is activated.
Disarm (by partition) – The call starts if the system or a partition is deactivated.
Bypass – The call starts if at least one zone is bypassed.
Wireless zone lost – The call starts if at least one wireless detector fails.
W. Low battery – The call starts if at least one wireless detector reports
Bell trouble – The call starts if the siren output is faulty.
False codes – The call starts if a bad PIN code is entered 3 times.
Low battery – The call starts if the standby power supply fails.
Wireless receiver jamming – The call starts if the radio traffic fails.
Bus trouble – The call starts if the internal bus fails.
to send the screen data and confirm with Yes.
For every phone number, double-
click Event. A new menu opens.
Select the events for whose reset
you want to be called by phone.
7-11