Start-Up Instructions
Once the spa is placed on a solid foundation and supplied with power, the spa should be filled and prepared for
use. For the best results, read each step completely before proceeding with the following steps.
1. Prepare the spa for filling.
Clear all the debris from the inside of the tub.
Wipe off and clean the acrylic with a wet towel to remove dust.
Remove the service door and tighten all the hand unions at the pump(s) and heater.
Ensure all the knife valves are in the open (UP) position.
2. Fill the spa.
A. Front Access Skim Filter (Rainier, Columbia, Chelan, Cascade)
Fill the spa through the opening until the water submerges all of the jets excluding the neck jets and
1/2 way up the opening of the weir gate. DO NOT let the water go below 1/2 of the way up the weir
gate assembly.
B. Pressure Filter Canister Assembly (Explorer, Triton, Gemini)
Locate the filter canister. Remove the lock ring and the filter lid. Remove
the filter element. Insert the garden hose into the filter canister and begin
to fill the spa. Once the water has filled the foot-well, add Stain & Scale
Defense (refer to the directions on the product label). Insert the hose into
the foot-well and continue to fill until the water is 1" above the wall jets
(excluding the neck jets) or covering 2/3 of the skimmer. Reinstall
the filter, lid and lock ring. The lock ring should spin and then lock into place.
Fill the tub with the garden hose until all jets excluding the neck jets are submerged.
C. Telescoping Filter Bucket (Discover, Saturn, Commander)
Using a garden hose with a pre-filter, fill the spa with pre-filtered water to the bottom of the pillows
8