Appion TEZ 8 Manuale operativo - Pagina 5
Sfoglia online o scarica il pdf Manuale operativo per Pompa di potenza Appion TEZ 8. Appion TEZ 8 14. Two stage vacuum pump
Positive Pressure Relief
If there is residual pressure in the system when the pump is attached to the system, the Debris
Monitor/Catch Tube will automatically disengage to relieve any positive pressure, preventing
damage to the TEZ8.
Once the pressure has been relieved, restart the TEZ8 and the suction will draw the tube back into
position, reseating itself on the double o-ring seal. If the catch tube does not reseat completely,
simply open the protective door and press the tube upwards into position.
Changing the Oil
It is a good idea to always use clean fresh oil in your Appion TEZ8 vacuum pump. This not only
prolongs the life of the pump, but also helps you to achieve a rapid and deep ultimate vacuum.
Changing the oil in the Appion TEZ8 is as easy as installing a new TEZOM oil cartridge following
the procedure below. Replacement TEZOM Oil Cartridges can be purchased from your local
wholesaler.
Note: Be sure to only use genuine Appion TEZOM Oil Cartridges in your TEZ8 vacuum pump to
ensure optimal performance. The use of other vacuum oil may inhibit the ultimate vacuum depth
that can be achieved.
Note: The re-use or refilling of an Appion TEZOM Oil Cartridge
may introduce contaminants and debris into the pump, resulting
in lost performance or damage to the TEZ8.
1.
Turn ON the Appion TEZ8 momentarily with one of the inlet
ports open to remove any residual oil from the pump. Then
turn the machine OFF and unplug from power source.
2.
Open the large door on the left side of the machine to gain
access to the TEZOM oil cartridge.
3.
While holding the lower part of the TEZOM, pull the
cartridge out of the side of the vacuum pump. (Fig. 1)
4.
Locate and remove the cap and protective seal from the
top of a new TEZOM. The cap can be used to seal the old
TEZOM for easy disposal. (Fig. 2)
Note: Dispose of the waste oil in accordance with your
local regulations.
5.
Locate the flat side of the new TEZOM and hold the
cartridge so that this is facing toward the machine.
6.
Place the oil suction tube into the new TEZOM and insert
the top of the TEZOM first to make sure the oil suction tube
remains inside the cartridge. (Fig. 3)
5
Fig. 1
Fig. 2
Fig. 3