CONVRTR-60 Connections
CONVRTR-60X
BATTERY INPUT
DCC OUT
Minus
Plus
B
3
1
2
4
5
6
CONVRTR-60 Board Familiarization
1. Battery Input Terminals: Connection to the battery goes here. The positive pad is labeled
with a + sign and the pad is square. The battery negative connection is to the round pad. The
CONVRTR-60 is polarity sensitive. Reversing the polarity will destroy the CONVRTR-60.
2. DCC Output Terminals : Connect these two pads to the DCC decoder. Use # 20 - #24 AWG
stranded wire to make all connections.
3. Green PWR LED Indicator: Glows bright green when power is applied.
4. Red GP LED Indicator: Glows steady bright red when an AirWire throttle is set to the
CONVRTR-60's frequency (regardless of loco address).
5. Radio Module: This is the sensitive radio receiver. Keep it away from metal objects. The
CONVRTR-60 on the right has a built-in antenna. It has a built-in antenna which is the dark oval
on the blue circuit board.
6. Removable Antenna: The CONVRTR-60X on the left has a jack for use with different types
of external antennas. A 3 inch whip antenna comes with the CONVRTR-60X. Keep the antenna
away from all wiring for best reception.
2 2
CONVRTR-60
BATTERY INPUT
Minus
A
Plus
3
1
4
Use Track Power? - Not Recommended, But...
The
CONVRTR-60
DCC OUT
power scavenged from some other form of track power can damage the battery and
B
A
possibly the
is highly discouraged.
However, we realize that this may be of interest to some users, especially if they intend to operate
their battery powered locomotive on powered track. There are no specific precautions for the
CONVRTR-60. However, it must stay within the absolute maximum ratings listed on the back page.
Use A Bridge Rectifier To Insure Proper Polarity for CONVRTR-60 Power Input. Insert a
2
bridge rectifier between the CONVRTR-60 DC input and the source of external DC power. Doing so
insures proper polarity regardless of the source power polarity.
Use Only Pure and Well Regulated DC. The power supply must be well regulated. It must not have
any ripple. A minimum specification of 5% regulation is recommended. CVP's DCPS120 power
supply can be used.
Set Power Supply Voltage to about 15 volts DC. The peak DCC voltage at the output of the
CONVRTR-60 will be approximately equal to the DC voltage at its power input terminals.
Clean Wheels And Clean Track Are Mandatory if power is not supplied by batteries.
Wiring The Railroad Is A Long And Boring Chore. If you use battery powered locomotives, there
is no need to worry about reverse-loops, turnout wiring, dead frogs, opposing point switch wiring,
route control wiring and the many other wiring requirements related to properly powering
locomotives through the rails.
AC
5
AC
Track
Pickups
DCPS120
Power Supply
The DCPS120 Power supply is a 120 Watt, adjustable DC power supply with excellent load
regulation. The output voltage is variable from 15V to 24V. It has built in overload and short circuit
protection. It is available direct from CVP Products. See the website for ordering details.
Warning
is designed for battery powered operation. Attempting to operate from
CONVRTR-60. Therefore attempting to use or recharge the onboard battery
10 Amp
50V
Bridge
Rectifier
Capacitor
2200uF/50V
Track Bus
Track Bus Wire - #18 AWG or Larger
All standard wiring requirements apply including proper
handling of reversing loops, power blocking,and track
feeders to each section of track. This is not a trivial task!
To DCC Decoder
Track Feeders
15