ADEMCO 5800WAVE Manuale di installazione e configurazione
Sfoglia online o scarica il pdf Manuale di installazione e configurazione per Sistema di sicurezza ADEMCO 5800WAVE. ADEMCO 5800WAVE 4. Wireless siren module
®
GENERAL INFORMATION
The 5800WAVE (Figure 1) is a wireless siren module that
contains an RF receiver and transmitter. The 5800WAVE
provides the following features:
•
May be used with the LYNXR Rev 10 or higher (with
RF enrollment) and LYNXR-EN self-contained controls
or with any other control that supports a 5883
Transceiver Module.
•
Transmits module status, including mounting tamper,
low battery, and AC loss to the control.
•
Transmits supervisory check-in message.
•
AC powered and mounts to any standard duplex
receptacle.
•
Contains a rechargeable battery that provides up to 12
hours of standby operation in the event of AC loss.
LED
Activates Upon
Yellow
Normally off. Blinks to indicate that an RF
message is being sent by the 5800WAVE.
steady during RF Link test.
Green
Normally on (lighted) when AC power is present.
Red
On when the system is armed. Off when the
system is disarmed.
indicates poor RF transmission.
INSTALLATION
To install the 5800WAVE siren, connect the battery, set the
house ID, and enable module supervision, follow the
instructions below.
1. The 5800WAVE must be installed on a
Listed duplex receptacle using the screw
provided.
2. Do not connect the 5800WAVE to a
receptacle controlled by a switch.
3. For 24 hours of standby operation and UL
Listed Fire Installations, use ADEMCO
battery part number WALYNX-RCHB-HC.
Note: The 5800WAVE must be powered overnight for the
battery to reach full capacity.
Connecting the Battery and Setting the House ID
Caution: When opening the case to connect the battery and
set the house ID, use care not to damage the wire leads
connected to the sounder and circuit board when separating
the case front from the back. Refer to figure 2.
1.
Remove the 4 screws located in the back of the unit.
2.
Check that the standby battery is held securely in place
by the two battery clips (Figure 2).
3.
Plug the standby battery connector into the PCB
connector as shown in Figure 2.
4.
Set DIP switches 4-8 to the appropriate House ID (1-31)
See Figure 3. The House ID set by the DIP switches
should match that entered in the control.
5.
Close the 5800WAVE's case and reinstall the 4 screws
removed in step 1.
INSTALLATION AND SETUP GUIDE
During RF Link test, on
Verifying The RF Link
Notes:
Dip switch 6 on the 5883 must be set to ON to enable its RF
transmitter.
The security system control must have the House ID set and
must not be in the Test Mode or Programming Mode when
checking the RF Link.
1.
Plug the 5800WAVE into the AC receptacle at the
desired location. The green LED will light indicating
AC is present and the 5800WAVE is powered.
yellow LED will light for approximately 15 seconds.
•
If the red LED turns on, the RF link is bad. Relocate
the 5800WAVE to another AC receptacle (closer to the
control) and repeat step 1 to verify the RF Link.
•
If the red LED remains off, the RF link is good and you
may complete the installation at this location.
2.
Unplug the 5800WAVE and proceed to "Enable Module
On
Supervision".
Enabling Module Supervision
The 5800WAVE is supervised by the control for loss of RF
check-in transmissions, low battery, loss of AC, and
mounting tamper.
The 5800WAVE reports AC loss and low battery as Low
Battery to the control (and will not cause an alarm when
the control is armed).
An AC loss exists if Low Battery is displayed on the control
keypad (with the programmed zone number) and the Green
LED on the 5800WAVE is off.
Program the 5800WAVE in the control as a zone and enroll
its serial number as described using the installation and
setup guide supplied with the control and the information
below.
Note the following when enrolling:
Zone type = 5 (trouble by day / alarm by night)
Input type = 3 (RF)
Loop number = 1
1.
When prompted for the serial number, you can either
enter it manually or transmit from the device.
a.
To enter the serial number manually, read the
number from the label on the device and enter it
via the control's keypad (referring to the zone
programming section of the Installation and Setup
Guide for the control).
b.
To
transmit
5800WAVE into an AC receptacle.
(within 15 seconds) place the tamper magnet next
to the tamper position indicator lines on the case
(figure 4) and wait until the yellow LED turns off,
and
transmission.
The yellow LED will flash when the transmission is
sent.
2.
When the enrollment is complete, exit programming
mode and unplug the 5800WAVE. Proceed to step 3 if
mounting tamper is desired.
Completing Installation.
K0584V1 Rev. B 2/03
Wireless Siren Module
the
serial
number,
then
remove
the
magnet
Otherwise proceed to
5800WAVE
The
plug
the
Immediately
to
cause
a