Great Plains Industries, Inc. HP-90 Manuale d'uso - Pagina 2

Sfoglia online o scarica il pdf Manuale d'uso per Pompa dell'acqua Great Plains Industries, Inc. HP-90. Great Plains Industries, Inc. HP-90 4. Petroleum hand pump

OPERATIONS
Observe safety precautions when handling fuel:
Keep fuel away from open flame or spark.
Do not refuel vehicles or equipment with engines run-
ning or while engine is hot.
Do not smoke while refueling.
Know and follow all safety precautions when handling
petroleum fluids
Insure that all equipment operators have access to ad-
equate instructions concerning safe operating and main-
tenance procedures.
To Dispense Fluid
1. Remove the nozzle from its holder and
insert into the receiving tank of the
equipment or vehicle.
2. To pump, manually
move the handle
front to back as
shown on right.
3. Return the handle
to its upright storage
position, after dis-
pensing the desired
amount of fluid. Drain
the hose and place
the nozzle in its holder.
TROUBLESHOOTING
A. Shaft Seal Leak
1. Seal worn. Replace (Seal Kit 131501-02).
B. Anti-Siphon Vent Leak
1. Vent damaged. Remove and clean or replace
(Kit 123504-1).
C. Low Flowrate
1. Inlet screen clogged. Remove pump and suction
pipe, clean screen and re-install.
2. Suction pipe leak. Repair or replace as needed.
3. Piston seals worn. Replace (Seal Kit 131501-02).
Back
Front
SPECIFICATIONS
The GPI HP-90 Petroleum Hand Pump is designed to manu-
ally pump petroleum products such as diesel fuel, kero-
sene and gasoline and fits any container with a 2-inch NPT
bung.
Construction:
Lightweight aluminum housing, stain-
less steel shaft and plastic piston
Capacity:
Up to 1 quart per stroke
Inlet Port:
1 inch NPT
Inlet Screen:
Integral with pump
Outlet Port:
3/4 inch NPT
Hose and Nozzle: 3/4 inch x 8 foot Buna-N hose. Ther-
moplastic unleaded nozzle
Suction Pipe:
2 piece PVC
Shipping Weight:
12.8 pounds (5.8 kg)
SERVICE
For warranty consideration or other service information,
please contact your local distributor. If you need further as-
sistance, contact the GPI Customer Service Department in
Wichita, Kansas, during normal business hours. A toll free
number is provided for your convenience.
1-800-835-0113
To obtain prompt, efficient service, always be prepared with
the following information:
1. The model number of your pump.
2. The manufacturing date code of your pump.
For the HP-90, the date code is located on the shaft side of
the pump housing.
For warranty work, always be prepared with your original
sales slip or other evidence of purchase date.
Please contact GPI before returning any pump. It may be
possible to diagnose the trouble and find a solution with a
telephone call. GPI can also inform you of any special re-
quirements you will need to follow for shipping.
! ! !
CAUTION
!
Do not return the pump without authority from the
Customer Service Department. Due to strict govern-
ment regulations, GPI cannot accept pumps unless
they have been drained and cleaned.
! ! !