ADEMCO VISTA-20P Series Manuale di programmazione - Pagina 5
Sfoglia online o scarica il pdf Manuale di programmazione per Sistema di sicurezza ADEMCO VISTA-20P Series. ADEMCO VISTA-20P Series 17.
Anche per ADEMCO VISTA-20P Series: Manuale di installazione rapida (2 pagine)
✱ 65
OPEN REPORT CODE
✱ 66
ARM AWAY/STAY RPT CODE
✱ 67
RF XMTR LOW BAT REPORT CODE
✱ 68
CANCEL REPORT CODE
RESTORE REPORT CODES ( ✱ 70 – ✱ 76)
✱ 70
ALARM RESTORE RPT CODE
✱ 71
TROUBLE RESTORE RPT CODE
✱ 72
BYPASS RESTORE RPT CODE
✱ 73
AC RESTORE RPT CODE
✱ 74
LOW BAT RESTORE RPT CODE
✱ 75
RF XMTR LO BAT RST RPT CODE
✱ 76
TEST RESTORE RPT CODE
OUTPUT AND SYSTEM SETUP ( ✱ 77 – ✱ 93)
✱ 77 DAYLIGHT SAVINGS TIME
START\END MONTH
✱ 78 DAYLIGHT SAVINGS TIME
START\END WEEKEND
∗ 79, *80, *81, *82
✱ 84
AUTO STAY ARM
✱ 85
CROSS ZONE TIMER
This option not for use in UL installations.
✱ 86
CANCEL VERIFY
✱ 87
MISC. FAULT DELAY TIME
(used with Configurable Zone Types "digit 6")
✱ 88
PROGRAM MODE LOCKOUT
OPTIONS
✱ 89
EVENT LOG FULL REPORT CODE
✱ 90
EVENT LOG ENABLES
✱ 91
OPTION SELECTION
www.PDF-Zoo.com
Part. 1 Part. 2 Common
Away Stay
Part. 1
MENU MODES
(assign cross zones on
zone list 4, using *81 Menu
mode)
NOTE : System messages are
logged when any non-zero
selection is made.
[0,0,0]
See box above.
Away Stay
Away Stay
Part. 2
Common
|
[00]
See box on previous page.
UL: must be enabled if wireless devices are used
|
[00]
See box on previous page.
[0]
See box on previous page.
|
[00]
See box on previous page.
|
[00]
See box on previous page.
|
[00]
See box on previous page.
|
[00]
See box on previous page.
|
[00]
See box on previous page.
UL: must be enabled if wireless devices are used
|
[00]
See box on previous page.
0 = Disabled
|
[4][10]
1-12 = January-September (1 = Jan, 2 = Feb, etc)
#+10 = October; #+11 = November; #+12 = December
0 = disabled, 1 = first, 2 = second, 3 = third
|
[1][5]
4 = fourth, 5 = last, 6 = next to last, 7 = third to last
These are Menu Mode commands, not data fields, for Output Device Mapping, Output
Programming, Zone List Programming, and Alpha Programming respectively. See
page 2 and their respective sections in the Installation and Setup Guide for procedures.
0 = no, 1 = partition 1 only
[3]
2 = partition 2 only, 3 = both partitions
0 = 15 seconds
[0]
1 = 30 seconds
2 = 45 seconds
3 = 60 seconds
4 = 90 seconds
5 = 2 minutes
0 = no, 1 = yes
[1]
0 = 15 seconds
[0]
1 = 30 seconds
2 = 45 seconds
3 = 60 seconds
4 = 90 seconds
5 = 2 minutes
UL: may only be used on non-burglar alarm/ non-fire alarm
zones when used in fire and/or UL burglar alarm installation
0 = standard *98 installer code lockout (reentry only by
[0]
1 = lockout [∗] + [#] reentry after *98 exit (reenter via
2 = not used
3 = lockout all local programming after *98 exit (reentry
See box on previous page for report code entries.
|
[00]
0 = None; 1 = Alarm/Alarm Restore
[3]
2 = Trouble/Trouble Restore;
4 = Bypass/Bypass Restore;
8 = Open/Close. Example: To select "Alarm/Alarm
Restore", and "Open/Close", enter 9 (1 + 8); To select
all, enter #15.
0 = None
[8]
4 = AAV UL: do not use AAV
8 = Exit Delay Restart/Reset UL: must be disabled
SIA Installations: Exit Delay should be enabled.
Multiple choice example: for AAV (4) + Exit Delay
restart (8) enter # + 12.
– 5 –
[0,0,0,0,0,0] See box above.
6 = 2-1/2 min
7 = 3 min
8 = 4 min
9 = 5 min
#+10 = 6 min
#+11 = 7 min
6 = 2-1/2 min
7 = 3 min
8 = 4 min
9 = 5 min
#+10 = 6 min
#+11 = 7 min
[∗] + [#] within 50 seconds after power up)
installer code only)
via downloader only)
#+12 = 8 min
#+13 = 10 min
#+14 = 12 min
#+15 = 15 min
#+12 = 8 min
#+13 = 10 min
#+14 = 12 min
#+15 = 15 min