ADEMCO LYNX Manuale del sistema - Pagina 7

Sfoglia online o scarica il pdf Manuale del sistema per Sensori di sicurezza ADEMCO LYNX. ADEMCO LYNX 14.
Anche per ADEMCO LYNX: Manuale d'uso (17 pagine), Manuale di avvio rapido (8 pagine)

ADEMCO LYNX Manuale del sistema
Ademco Lynx System Manual
should also be lit.
4. Enter your [user code] and then press [TEST].
5. The external sounder should sound for 2 seconds and then turn off.
FAULT ZONES. Open each protected door and window in turn and listen for three beeps from the
keypad. Identification of each faulted protection point should appear on the display. The display will clear
when the door or window is closed.
Walk in front of any interior motion detectors (if used) and listen for three beeps. The identification of the
detector should appear on the display when it is activated, and its voice descriptor will be announced (if
programmed). The display will clear when no motion is detected. Note that if wireless motion detectors
are used, there is a 3-minute delay between activations. This is to conserve battery life.
To test all smoke detectors, follow the manufacturer's instructions. The identification of each detector
should appear on the display when each is activated.
If a problem is experienced with any protection point (no confirming sounds, no display), notify your
service company.
When all protection points have been checked and are intact (closed), there should be no zone
identification numbers displayed on the keypad

Exit Test Mode

When testing is completed, exit the Test Mode by entering your [security code] and pressing the [OFF]
key.
If the Test Mode is inadvertently left active, it will automatically turn off after 4 hours.
To learn more about testing your system, please visit
Other System Information
For a more detailed description of these features, please refer to the manufacturer's complete manual.
Time & Date Programming
Your system can display the current time. The date is not displayed, but has an internal function. The
system must be disarmed with no faults present.
To set the time and date, enter the [Master code] and press [FUNCTION] and enter [63].
NOTES:
http://alpha.adt.com/help/261[11/14/2018 8:02:22 PM]
System
Testing.