DBI SALA Flexiguard 8530564 Manuale di istruzioni per l'installazione - Pagina 4

Sfoglia online o scarica il pdf Manuale di istruzioni per l'installazione per Attrezzatura di sicurezza DBI SALA Flexiguard 8530564. DBI SALA Flexiguard 8530564 8. Concrete mounted jib base
Anche per DBI SALA Flexiguard 8530564: Manuale di istruzioni (18 pagine)

Step - 3: Installing the Jib Mast into the Jib Base.
• Lower the Jib Mast until the Rotation Block (A) is resting in the Locking Slot (B) in the Jib Base. (See
Figure 4 -
.)
A
IMPORTANT: Insert the Base Cap into the Jib Base when the Jib Mast is not in the Jib Base.
INSPECTION:
IMPORTANT: Extreme working conditions (harsh environments, prolonged use) may require increasing the
frequency of inspections..
WARNING: If the system has been damaged do to fall arrest, it must be immediately removed from service,
inspected, or contact Capital Safety for repair or replacement.

Before Every use:

• All fasteners must be tight, secure and not damaged.
• Inspect for corrosion or rust.
• All labels must be present and fully legible.
• Inspect for cracks around the Jib Base.
• Record results of inspection in the inspection and maintenance log provided.
• If inspection reveals an unsafe or defective condition, remove Concrete Mounted Jib Base from service
and destroy, or contact Capital Safety for repair or replacement.
Monthly:
• A formal inspection should be done by a Competent Person
inspection in the inspection and maintenance log provided.
LABELS
:
A
B
C
D
1 Competent Person:
One who is capable of identifying existing and predictable hazards in the surroundings or working conditions which are unsanitary, hazard-
ous, or dangerous to employees, and who has authorization to take prompt corrective measures to eliminate them.
9511992 rev.c
4
other than the user. Record results of
1
C
D
B
A
(See Figure 4 -
B
.)
B