Autopilot APCEPH1 Manuale di istruzioni - Pagina 2
Sfoglia online o scarica il pdf Manuale di istruzioni per Controllore Autopilot APCEPH1. Autopilot APCEPH1 13. Ph controller
INSTRUCTION MANUAL
Basic Description
The APCEPH1 has been designed to accurately and reliably measure and control the pH
of any aqueous (water-based) solution, including hydroponic nutrient mixtures as well as
fish aquariums. It does this by measuring the pH level of the water to be controlled and
then it will automatically add pH adjustment (EITHER acid or alkali) to change the liquid's
pH to the user's desired level.
single direction (either raising OR lowering of the pH).
The user can select their desired pH setting from 4.5 to 8.5 pH. Many other adjustable
settings allow the APCEPH1 to be customized by the user for their specific needs. For best
results, read and follow these instructions.
principal of operation
The APCEPH1 consists
of several components.
Understanding how
these components work
together is critical to
getting the most from the
APCEPH1.
1. sensors: Two
sensors are provided
with the system, a
temperature sensor
and a pH sensor. The
sensors are connected
to an in-line sensor
interface cable. The
sensors are then
inserted into the
"sampling assembly".
2. apcepH1sK -
sampling assembly
(optional / sold
separately): For
best results, the
sensors should have
a constant flow of
water to ensure
they are accurately
measuring the pH
and temperature. The
sampling assembly
holds the two sensors
and provides water
flow across the
sensors to accurately
measure the water
temperature and pH
level.
2
Note: Most water solutions will slowly change pH over time in a
1. sensors
Sensor interface
connects to
controller
2. saMplinG
asseMBlY*
SAM-1
Sampling
assembly
Water
inlet
*Sold separately
pH sensor
probe
Temperature
sensor probe
www.hydrofarm.com
pH and
temperature
sensors inserted
into sampling
assembly
Water outlet