Cleaning
DISCONNECT POWER CORD BEFORE CLEANING ANY PARTS OF THE UNIT.
It is strongly recommended that any servicing of the unit be performed by an authorized service technician.
Fan Blades & Motor
• If necessary, clean the fan blades and motor with a soft cloth.
• If it is necessary to wash the fan blades more thoroughly, cover the fan motor to prevent moisture damage, then
use a damp cloth to clean the fan blades.
Interior
• Use warm water and a mild soap with a clean cloth to wipe down the interior of the unit.
• DO NOT use steel wool, caustic soap, abrasive cleaners, or bleach that may damage the interior finish.
• Wash door gaskets on a regular basis, preferably weekly. Simply remove door gasket from the frame of the
door, soak in warm water and soap for thirty (30) minutes, dry with soft cloth, and replace.
• Check door gaskets for proper seal after they are replaced.
• Periodically remove the shelves and pilasters from the unit and clean them with mild soap and warm water.
To remove the pilasters, first remove the shelves and shelf brackets. Then, simply lift the pilaster up and out.

Cleaning the Condenser Coil

• A dusty condenser may lead to high energy consumption, less cooling effectiveness, and compressor damage.
• For efficient operation, keep the condenser surface free of dust, dirt, and lint.
• We recommend cleaning the condenser coil at least once per month.
• The condenser coil is located at the bottom behind the panel.
Cleaning the Condenser Coil Instructions
1. Disconnect the electrical power from the unit.
2. Remove the front cover and base cover with a screwdriver.
3. Using a soft brush and/or vacuum, remove the dirt, lint, etc. from the finned condenser coil in a vertical
direction.
4. Clean the condenser with a commercial condenser coil cleaner, available from any kitchen equipment
retailer. Ex. Noble Chemical Tech Line Coil Cleaners (148TLECCCLNR, 148TLHDCCLNR, 148TLECOILDD,
148TLFMCCLNR, 147TLEVPCLNR, or 147TLHDCCLNR).
5. After cleaning, straighten any bent condenser fins with a fin comb.
6. When finished, be sure to reinstall the front cover and base cover.
7. Reconnect the electrical power to the unit.
User Manual