 The fan must be installed so that the blades are more than 2.1 meters above the floor.
 According to law in Australia, all electrical connections & disconnection must be installed by licensed
electrician. This ceiling fan fall within this requirement.
 According to our warranty terms, only ceiling fans installed by licensed electrician are covered under
warranty.
Always check the "Trouble Shooting Checklist" included in this booklet before calling for service. Unnecessary
calls are inconvenient for all and can attract a service charge.
For your safety, ensure the ceiling fan is OFF before carrying out any troubleshooting.
TROUBLE
1. Fan will not start
(Warning: THE ceiling
must be switched OFF,
and the assistance of a
licensed
electrician
maybe required.)
2. Fan Wobbles
(Refer
to
Wobble
section of the manual
for further information.)
3. Fan sound noisy
4. Mechanical Noise
5. Light will not turn
ON (Optional light kit
ONLY)
WARNING: THE CEILING FAN MUST BE SWITCHED OFF, BEFORE TROUBLE
SHOOTING IS PERFORMED.
13
TROUBLE-SHOOTING CHECKLIST
PROBABLE CAUSES
A. Fuse or circuit breaker blown. Check main and branch circuit fuses or
B. Loose power connections to
the fan. (normally occur during
installation.
C. No response from the remote
transmitter
D. Switch the Fan ON via the
mains switch.
A. Fan blades are not horizontal
to ceiling.
B. Blade screws are loose.
C. Blade/s are out of shape
A. Top canopy touching ceiling.
B. Loose fan blade screws.
C.
Ceiling
fan
not
against ceiling.
D. Incorrect speed controller.
A. Allow at least for 8 hours
settling-in period.
The globe/lamp has failed.
WARNING
circuit breakers.
Check power connections to fan. Must be
performed be a Licensed Electrician.
- Battery is low. Replace batteries.
- Check if correct remote transmitter is paired
with the receiver.
Check if there is power to the fan.
Refer to "wobbling fixing" section of manual.
-
The blade may require adjustment at the
blade mounting screws;
-
The blade is out of shape, thus causing
wobbling. New blades set will require to
be replaced. Contact retailer for further
details.
Make sure all screws are securely fastened.
Remove blade and lay on a flat surface to check
if blades are out-of-shape. Contact retailer for
further details.
Lower Canopy from ceiling to ensure minimum 3
mm clearance.
Re-tighten all screws on fan blades but never
over-tighten.
secured
Re-tighten all screws in the hanging bracket or
plate.
Change the controller to the one supplied.
(Must be performed by a Licensed Electrician.)
SUGGESTED REMEDY
Replace globe/lamp