Kohler K-1151 Manuale di installazione - Pagina 8

Sfoglia online o scarica il pdf Manuale di installazione per Vasche da bagno Kohler K-1151. Kohler K-1151 36. Bath with airjets
Anche per Kohler K-1151: Manuale del proprietario di casa (29 pagine), Manuale del proprietario di casa (36 pagine), Manuale del proprietario di casa (32 pagine), Manuale di installazione (48 pagine), Manuale del proprietario di casa (36 pagine), Manuale di messa a punto (4 pagine), Manuale di installazione (48 pagine), Manuale del proprietario di casa (29 pagine)

Kohler K-1151 Manuale di installazione
Bond in accordance
with applicable codes.

7. Make Electrical Connections

WARNING: Risk of electric shock. To reduce the risk of electrical shock, connect the pump and in-line
heater (if heater option included) to properly grounded, grounding-type receptacles protected by
Ground-Fault Circuit-Interrupters (GFCI's). Do not remove the plugs' grounding pins. Do not use
grounding adapters.
NOTE: The whirlpool model number is printed on a label near the whirlpool pump. This label also
identifies the electrical rating of the whirlpool.
Your Kohler whirlpool bath is equipped with a cord and plug. All of the heater wiring has been
completed at the factory. A licensed electrician must install a GFCI-protected, 120 V, 15 A, grounded
outlet.

Pump Wiring

NOTE: The whirlpool model number is printed on a label near the whirlpool pump. This label also
identifies the electrical rating of the whirlpool.
Your Kohler whirlpool bath is equipped with a cord and plug. All wiring of the pump and control
has been completed at the factory. A licensed electrician must install a GFCI-protected, 120 V, 15 A,
grounded outlet. No other load should be on this circuit. Locate the outlet behind the whirlpool,
and within 24" (61 cm) of the pump.
Plug the pump into this outlet.
NOTE: Make sure the air actuator tubing is securely attached to the pump, and is not kinked or damaged.
If a K-1639 Timer Kit will be used, install it now according to the instructions packed.

In-Line Heater Wiring

"H" Models: The heater is equipped with a cord and plug. All wiring of the heater has been
completed at the factory. A licensed electrician must install a GFCI-protected, 120 V, 15 A, grounded
outlet. No other load should be on this circuit. Locate the outlet behind the whirlpool, and within
24" (61 cm) of the heater.
Plug the heater into this outlet.
1012295-2-D
Heater
Plug the pump
into this outlet.
Install a GFCI-
protected 120 V, 15 A
grounded outlet.
8
Install second GFCI-
protected outlet for "H"
models for the in-line heater.
Kohler Co.