Basic Troubleshooting
Problem/Report
No Water Dispensing
Warm Drinks
Water lying on top edge of
lower door panel and/or
bottom of cabinet.
Water lying in bottom of
machine.
Bleeping Noise
Possible Cause
Water supply turned off.
"Leak detector"" (if fitted) tripped off.
Faulty water pressure regulator, or other
failure.
Insufficient cooling air flow through the
fridge.
Faulty compressor, or other failure.
Overflowing drip tray waste container.
Leak in pipe work and/ or filter.
Level sensor fitted and tank full.
Suggested Action
Check that power supply, and all taps/ valves/
filters on the incoming water supply are fitted
and are turned on.
Disconnect the power and water supply, check
for leaks. To reset the machine contact your
distributor.
Contact your distributor.
Contact your distributor.
Empty waste container and check drainpipe is
not blocked.
Contact your distributor.
Empty level sensor tank.