Installation
Recirculation connection
Recirculation mode is used when
venting to the outside of the building is
not possible.
^ Slide the diverter on to the brackets
of plate B.
^ Slip the hose clamps over the flex
hose onto the diverter and the motor
assembly exhaust connection. Once
in place, tighten the hose clamps.
Active charcoal filters must be used
in the recirculation mode.
36
Attaching the chimney
extension
The use of a chimney extension, allows
the hood to be installed at various
distances from the ceiling.
NOTE: The extension must be
intalled in relationship to the method
of venting; Extraction or
Recirculation.
Recirculation
The extension piece has vented
openings on one end.
These vents are required for recir-
culation mode and will be closest to the
ceiling when installed.
For air extraction, the vents are not
required and are covered by the
chimney.