When replacing the grease filters make
sure the locking clips are visible facing
down towards the hob.
Should the grease filters be put back
upside down:
insert a small screwdriver into the slits
to disengage them. Do not let them
drop on to the hob below.
^ After replacing the grease filters,
press the grease filter touch control
for approx. 3 seconds to re-set the
operating hours counter.
The indicator lamp will go out.
^ If the grease filters are cleaned be-
fore the operating hours counter has
reached its maximum, the grease fil-
ter touch control should be pressed
for approx. 6 seconds to reset the
counter to zero.