Installation
Secure the exhaust ducting to the
exhaust socket, e.g., with a hose clip
(available as an optional accessory)
on flexible ducting.
Vented mode
See "Connection for vented mode"
for additional instructions on
attaching the ducting.
32
Recirculating mode
If site conditions are not suitable for use
with air extraction, the downdraft must
be set up for recirculation. There are
several options for this:
– connect a DUU 151 recirculation
conversion kit to the exhaust
socket. The downdraft grease filters
must be fitted with DKF 22-1
charcoal filters (see "Cleaning and
care")
or
– Connect the recirculation box
DUU 2900 to the exhaust socket.
The charcoal filters are integrated in
the recirculation box. Therefore,
charcoal filters do not have to be
fitted in the downdraft.
Conversion kits DUU 151 and
DUU 2900 are available as optional
accessories.
See the relevant installation
instructions for more information.