Miller Axcess 675 Manuale d'uso - Pagina 17
Sfoglia online o scarica il pdf Manuale d'uso per Sistema di saldatura Miller Axcess 675. Miller Axcess 675 48. Automatic welding interface and arc welding power source
Anche per Miller Axcess 675: Manuale d'uso (48 pagine)
3-8. Connecting To Weld Terminals
.
If using an electrode negative (straight polarity)
process, the volt sense lead must be connected
to the work.
Tools Needed:
3/4 in (19mm)
Y Turn off power before connecting to
weld output terminals.
Y Failure to properly connect weld
cables may cause excessive heat
and start a fire, or damage your
machine.
Determine total cable length in weld circuit
(both positive
and
negative
combined)
and
maximum
amperes. See Section 4-1 to select proper
1
6
3
Do not place
anything between
weld cable terminal
and copper bar.
4
5
Correct Installation
cable size.
1
Positive (+) Weld Output Terminal
2
Negative (−) Weld Output Terminal
Connect positive weld cable to Positive (+)
weld terminal and negative (−) cable to
Negative weld terminal.
3
Weld Output Terminal
cables
4
Supplied Weld Output Terminal Nut
welding
5
Weld Cable Terminal
2
Incorrect Installation
6
Copper Bar
Remove supplied nut from weld output
terminal. Slide weld cable terminal onto
weld output terminal and secure with nut so
that weld cable terminal is tight against
copper bar. Do not place anything
between weld cable terminal and copper
bar. Make sure that the surfaces of the
weld cable terminal and copper bar are
clean.
803 822-A / 803 778-A
OM-217 751 Page 13