E. ELECTRICAL CONNECTIONS AND WIRING
5. INTERFACING DIGITAL LOGIC CONTROL MODELS
with Jandy™Aqualink RS & Compool
To interface the "Digital Logic" digital control heat pump models with the Jandy AquaLink RS series
or Compool, run a 2 wire (16 A.W.G. or larger) insulated cable from the device to the heat pump.
Remove the 6 screws from the heaters front service access panel and open. Look for the heater's
solid state circuit board located inside the top portion of the electrical compartment mounted on the
rear wall. Locate, remove and discard the "METAL JUMPER TAB" attached to the bottom terminal
bar and labeled "Jandy/Compool". Then, run a 2 wire cable from the 2 position terminal where the
metal jumper tab was, through the heater's low voltage access port, then to the AquaLink RS or the
Compool control.
NOTE for AquaLink RS and Compool: Turn both heater thermostats all the way up and set the
mode selector switch to pool and do not use the heater controls as the Jandy or Compool now has
thermostatic control over the heater.
for AquaLink
Attach the 2
wire cable to
positions #1
and position
# 2 on the 10
slot, green ter-
minal bar inside
the AquaLink's
power center.
*See the con-
trollers instal-
l a t i o n g u i d e
also.
FOR AQUALINK/COMPOOL
REMOVE METAL JUMPER
GREEN TERMINAL BAR
POSITIONS 1 & 2
JANDY AQUALINK PC BOARD
JUMPERS
SEE
NOTE #4
P
COM.
S
OR
PR
WH
2 WIRE CABLE
#14-16 AWG
TERMINAL
"HTR" POSITIONS
COMPOOL
PC BOARD
9
for Compool
Attach the 2
wire cable to
the Compool's
power center
board located
on the termi-
nals labeled
"HTR"
*See
the controllers
i n s t a l l a t i o n
guide also.
TN