Operational Instructions

When heating the pool or spa you should check the following items as they are
all critical to the proper operation of the heater.
1. WATER FLOW
Make sure all pool filters and traps are clean since the unit requires a minimum
water flow in order to operate properly. The heater should and will not run un-
less the water pump is running. There is an internal water pressure switch that
disables the heater whenever the water pump is not supplying water flow.
2. WATER PUMP TIMER SETTING
Since the heat pump collects heat from the outside air, you want to set the water
pump timer to run during the hottest part of the day. If you are heating the pool
from "dead cold" you may need to set the water pump timer to run 24 hours
until the pool reaches temperature, then reset the timer for a normal run time.
Run times are determined by pool size, set pool/spa temperature and weather
conditions.
3. THERMOSTAT SETTING & MODE SELECT
BUTTONS
The LED display will show a constant readout of the
actual current water temperature. To set the desired
water temperature press either the + or - thermostat
buttons. While adjusting the set temperature, the
LED will flash. The flashing numbers will indicate
the thermostat setting.
If you have a spa you can press the spa mode button and set the desired spa
temperature. If you do not have a spa use the pool mode only.
4. OPTIONAL TIME CLOCK OVERRIDE SWITCH
The optional "Time Clock Override" control you can set the switch
turn this switch ON and the heater will start the water filter pump
automatically whenever the water temperature drops below the

thermostat setting.

This option is best used when heating the pool from "dead cold" and for main-
taining water temperatures during non timed periods where the pool is losing 8
to 10 degrees or more overnight. The heating mode select switch is best left in
the OFF position during the warmer parts of the swimming season. The optional
time clock override feature is built into the heater at the factory and can not be
Page 6