heater to remain off for a few hours. If the water draining from the heater has slowed
considerably, this would indicate that the water present was from normal condensa-
tion. If the water has not slowed, this would indicate a leak.
It is important to keep the drain holes located around the bottom of the unit clean and
free of debris that might accumulate. Keep plants from growing near or next to your
heater. Shrubs, especially, block air from entering the machine and reduce the effi-
ciency of the heater. Eventually, this can cause damage to the unit if left uncorrected,
Keep all shrubs at least 1 foot away from the outer coil of the heater.
8.
SURROUNDINGS
While the heat pumps are made for an outdoor environment, they are not designed
to have sprinkler water constantly spraying them. Water used to irrigate can contain
iron and other minerals that can coat the heat collectors, causing poor heat transfer or
eventually damaging the air coils and other internal components. Premature rusting
of components is a frequent symptom of the sprinkler system striking the unit and is
not covered by the warranty.
9.
POOL BLANKETS
A pool blanket will significantly reduce your heating bills. You should check with
the installing dealer to see if your heat pump was sized to be used in conjunction with
a solar blanket or without one. Blanketed pools will typically lose only 2-4° of heat
per night versus 8 - 10° overnight in unblanketed pools. Reductions of 40-60% on
heating bills can be achieved by using solar blankets.
10.
SEASONAL SHUT DOWNS
During the swim season, even if the pool or spa is not in use, allow water to flow
through the unit. This eliminates the possibility of chlorine gas from your chlorinator
accumulating inside the heat exchanger.
See page 4 - C3
11.
WATER TREATMENT
AT500 Aquatherm Heat Pump is equipped with an internal bypass that allows only
the proper amount of water to flow through the heat exchanger. A Hartford Loop
MUST be installed between any chlorinator and the heat pump (see drawing on page
4).
Chlorinators must be installed downstream of the heat pump. The proper sequence
of installation is: pool pump - filter - heat pump - chlorinator (or other chemical
feeder device). Locating a chlorinator in any other manner may compromise the
warranty of your heat pump. Adding chemicals such as sanitizers or pH controllers
through the skimmer of your pool should be avoided. Not only can they damage the
heat pump, but other pool or spa equipment such as pumps and filters as well.
Suction type sanitizers that utilize the vacuum created in the pool pump strainer to
pull chemicals into the water are safe to use when installed in accordance with the
manufacturer's instructions. The chemicals injected into the pool water before the
pool pump are well dispersed by the time they go through the heat pump and will not
cause harm when operated as per the manufacturer's instructions.
8.