Axor Citterio Select 39863 7 Series Manuale di istruzioni per l'uso - Pagina 3
Sfoglia online o scarica il pdf Manuale di istruzioni per l'uso per Prodotto idraulico Axor Citterio Select 39863 7 Series. Axor Citterio Select 39863 7 Series 16.
S A F E T Y N O T E S
Gloves should be worn during installation to prevent crushing and cutting injuries.
The hot and cold supplies must be of equal pressures.
I N S T A L L A T I O N I N S T R U C T I O N S
⁄ Prior to installation, inspect the product for transport damages. After it has been
installed, no transport or surface damage will be honoured.
⁄ The pipes and the fixture must be installed, flushed and tested as per the applicable
standards.
⁄ The plumbing codes applicable in the respective countries must be observed.
⁄ During initial start-up and after servicing, air in the fittings can cause noise. After
switching the jet on and off about 15 times, the noise will stop.
T E C H N I C A L D A T A
Operating pressure:
Recommended operating pressure:
Test pressure:
Hot water temperature:
Thermal disinfection:
The product is exclusively designed for drinking water!
S Y M B O L D E S C R I P T I O N
Do not use silicone containing acetic acid!
A D J U S T M E N T (see page 06)
To adjust the hot water limiter. Using a hot water limiter in combination with a
continuous flow water heater is not recommended.
M A I N T E N A N C E (see page 08)
The check valves must be checked regularly according to EN 806-5 in
accordance with national or regional regulations (at least once a year).
D I M E N S I O N S (see page 07)
F L O W D I A G R A M (see page 07)
S P A R E P A R T S (see page 10)
XX = Colors
00 = Chrome Plated
14 = Brushed Bronze
34 = Brushed Black Chrome
C L E A N I N G (see page 09)
O P E R A T I O N (see page 08)
⁄ Hansgrohe recommends not to use as drinking water the first half liter of
water drawn in the morning or after a prolonged period of non-use.
⁄ Minor leaking may occur briefly at the spout when opening the fitting via
the lever.
F A U L T
⁄ Mixer stiff
⁄ Mixer dripping
⁄ Water escaping in area of swivel spout
⁄ Water escaping at the threaded base
⁄ Hot water temperature too low
⁄ Low flow with Select valve after valve replacement
⁄ Select button stiff
A S S E M B L Y (see page 04)
max. 1 MPa
0,1 - 0,5 MPa
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
max. 60°C
70°C ⁄ 4 min
C A U S E
⁄ Cartridge defective, calcified
⁄ Cartridge defective
⁄ O-ring defective
⁄ connection hoses not completely screwed into basic body
⁄ O-ring at the connection hose defective.
⁄ Hot water limiter incorrectly set
⁄ Improper Select valve installed
⁄ Select button soiled
⁄ Use the lever to open the tap and set the desired temperature. The water
flow can be paused by pressing the Select button on the face side of the
spout. When the tap is not used for a longer period of time, f.e. when
retiring at night or leaving the house, it must be closed completely by
means of the lever.
R E M E D Y
⁄ Exchange cartridge
⁄ Exchange cartridge
⁄ Exchange O-ring
⁄ Tighten connection hoses by hand
⁄ Exchange O-ring
⁄ Set hot water limiter
⁄ Replace Select valve (#98463000)
⁄ Clean Select button and grease _3w O-ring
(see page 10)
0 3
EN